express water ro5dx making a weird gurgling or spurting noise from the faucet, not a steady stream.

— asked by Morgan

Quick answer: The "gurgling" or "spurting" effect in an Express Water RO5DX system is almost always caused by air pockets trapped within the internal plumbing or a loss of pneumatic pressure in the pressurized storage tank. When air is trapped in the lines, it creates a "slug" of gas that disrupts the laminar flow of water, causing the faucet to sputter as the air escapes in bursts.

Diagnosis

The "gurgling" or "spurting" effect in an Express Water RO5DX system is almost always caused by air pockets trapped within the internal plumbing or a loss of pneumatic pressure in the pressurized storage tank. When air is trapped in the lines, it creates a "slug" of gas that disrupts the laminar flow of water, causing the faucet to sputter as the air escapes in bursts. This is common immediately after a filter replacement or if the system has been sitting idle for several days. However, if the spurting occurs specifically when the tank is nearly empty, it indicates a failure in the tank's internal bladder. The RO5DX uses a diaphragm tank that relies on a specific air charge to push water up to the faucet. If this air charge is too low, the water doesn't exit the tank with enough force to maintain a steady stream, leading to a "coughing" effect where water and air mix at the spout. You can confirm this by checking if the tank feels heavy (full of water) but only provides a few seconds of steady flow before the spurting begins.

How to Fix It

To resolve air pockets and restore the correct pressure balance, follow these exact steps:

  1. Purge the Lines: Open the RO faucet fully and let it run. If the water spurts, keep it open. If the flow stops completely, close the tank valve (the small plastic valve on top of the storage tank) and open the faucet again. This forces the system to produce water in real-time, pushing air pockets out through the faucet. Run this for 5-10 minutes.
  2. Empty the Tank: Close the cold water supply valve to the system. Open the RO faucet and leave it open until the water stops flowing completely. This ensures the bladder is fully collapsed and ready for a pressure reset.
  3. Check the Air Charge: Locate the air valve (Schrader valve), which is usually tucked into a plastic cap on the side or bottom of the RO5DX storage tank. Use a low-pressure digital gauge to measure the PSI.
  4. Adjust Pressure: If the pressure is below 7 PSI (empty tank state), use a bicycle pump or small compressor to add air. Pump until the gauge reads exactly 7 to 10 PSI. Do not exceed 10 PSI, as this will reduce the actual water capacity of the tank.
  5. System Reset: Close the faucet, open the cold water supply valve, and open the tank valve. Allow the system to fill completely (usually 2-4 hours) before testing the flow again.

If That Didn't Work

  • Inspect for Micro-Leaks: Check the push-fit connectors on the 5-stage manifold. A tiny pinhole leak on the suction side of the system can allow air to be drawn into the line, creating a continuous cycle of air bubbles. Use a piece of damp paper towel to wipe every joint; if the towel catches a drop, trim 1/4 inch off the tubing and re-seat it firmly into the fitting.
  • Replace the Storage Tank: If you pump the tank to 7-10 PSI but it leaks air out of the Schrader valve within 24 hours, the internal rubber bladder has perished. No amount of pumping will fix a ruptured bladder; you must replace the tank entirely to restore a steady stream.
  • Check the ASO Valve: If your model includes an Automatic Shut-Off (ASO) valve, ensure it isn't partially clogged. A restricted ASO valve can cause erratic pressure fluctuations that manifest as spurting at the faucet.
  • Verify Feed Water Pressure: Use a house pressure gauge to ensure your incoming cold water is at least 40 PSI. If your home pressure is too low, the RO membrane cannot create enough head pressure to push air out of the lines efficiently.

Heads Up

  • Avoid Over-Pressurizing: Never pump the storage tank to "standard" tire pressures (30+ PSI). This will permanently deform the bladder and significantly reduce the amount of purified water the tank can hold.
  • Filter Seating: When replacing the three pre-filters, ensure the O-rings are lubricated with a tiny bit of food-grade silicone grease. A pinched O-ring can let air bleed into the system.
  • Flush New Membranes: Always run the system for at least 2 full tank cycles after a membrane change to remove preservative solutions and trapped air.
  • Periodic Pressure Checks: Check the tank air pressure every 6 months. It is normal for the tank to lose a small amount of air over time.