my apec roes-50 ro system has no water coming out of the faucet at all, what's wrong?

— asked by Jamal

Quick answer: When an APEC ROES-50 system produces zero output at the faucet, the issue is almost always a total loss of pressure within the system, preventing water from being pushed through the final stage and out of the dedicated faucet. This typically happens because the feed water supply has been accidentally closed, the internal storage tank has lost its air charge (pressure), or there is a catastrophic blockage in the 1/4" LLDPE tubing.

Diagnosis

When an APEC ROES-50 system produces zero output at the faucet, the issue is almost always a total loss of pressure within the system, preventing water from being pushed through the final stage and out of the dedicated faucet. This typically happens because the feed water supply has been accidentally closed, the internal storage tank has lost its air charge (pressure), or there is a catastrophic blockage in the 1/4" LLDPE tubing. To confirm the root cause, check the pressure gauge if your model is equipped with one, or perform a "tank bypass test." Close the blue tank valve (the handle on top of the storage tank). If water still trickles out of the faucet, the RO membrane is working, but the tank is empty or failed. If there is absolutely no flow with the tank valve closed, the problem is upstream—either the feed water valve is shut, the pre-filters are completely clogged with sediment, or the Auto Shut-Off Valve (ASO) has malfunctioned and is permanently closing the line.

How to Fix It

Follow these steps in precise order to restore water flow to your APEC ROES-50 faucet:

  1. Verify the Feed Water Adapter: Locate the brass adapter connected to your cold water pipe. Ensure the small lever handle is positioned parallel to the tubing (vertical/open). If the handle is perpendicular to the tubing, the water supply is cut off.
  2. Inspect the Main Cold Water Supply: Ensure the shut-off valve for the entire sink area is fully open. If your kitchen faucet works, this step is confirmed.
  3. Check the Storage Tank Valve: Locate the blue plastic valve on top of the pressurized storage tank. Ensure the handle is in the "Open" position (parallel to the tubing). If this valve is closed, no water can exit the tank to the faucet.
  4. Test the Storage Tank Pressure: If the tank feels heavy (full of water) but nothing comes out of the faucet, the internal bladder has lost its air charge. Use a standard tire pressure gauge on the Schrader valve (usually located on the side or bottom of the tank under a plastic cap). The pressure should be 5-7 PSI when the tank is empty.
  5. Clear Air Locks: If you recently changed filters, air may be trapped. Open the RO faucet and let it sit for 10 minutes. If no water flows, briefly open the bleed valve on the membrane housing (if applicable) to force air out of the system.

If That Didn't Work

  • Replace the Pre-Filters: If the sediment and carbon blocks (the first three canisters) are completely saturated or clogged with scale, water cannot reach the membrane. Replace the 5-micron sediment filter and the two GAC carbon filters. If the filters are blackened or slimy, they were the bottleneck.
  • Check for Kinked Tubing: Inspect the 1/4" red, yellow, and blue tubing. A single sharp kink in the line leading to the faucet or from the tank can completely block flow. Straighten any bends or cut and re-insert the tubing into the push-fit connectors.
  • Test the Auto Shut-Off (ASO) Valve: The ASO valve is the square block where four tubes meet. If the internal diaphragm fails, it may shut off the water flow even when the tank is empty. Disconnect the feed water line from the ASO valve; if water flows from the feed line but not through the ASO, the valve is defective and must be replaced.
  • Check the RO Membrane: If the system is making a constant "hissing" sound (waste water running) but the tank never fills, the membrane (the large center canister) may be fouled or ruptured. Replace the membrane element (typically a Dow Filmtec or APEC equivalent).

Heads Up

  • Air Pressure Maintenance: Always check the tank air pressure when replacing the membrane; a tank with 0 PSI will not push water to the faucet even if it is full.
  • Sanitization: If the system was dry for more than a week, flush the system by filling the tank and draining it completely two times before drinking the water to remove stagnant air and biofilm.
  • Leak Detection: After fixing a blockage, run the system for 30 minutes and wipe all push-fit connections with a dry paper towel to check for "weeping" leaks.
  • Filter Schedule: To prevent total flow failure, replace the three pre-filters every 6 months and the membrane every 24 months.