the fan runs but it doesn’t seem to pull air through the front grille very strongly

— asked by Riley

Quick answer: The lack of suction at the front grille of the Honeywell DH70W is typically caused by a restriction in the airflow path, which prevents the centrifugal fan from creating a vacuum. This occurs most frequently when the evaporator coils (the aluminum fins behind the filter) become saturated with dust, pet hair, or lint.

Diagnosis

The lack of suction at the front grille of the Honeywell DH70W is typically caused by a restriction in the airflow path, which prevents the centrifugal fan from creating a vacuum. This occurs most frequently when the evaporator coils (the aluminum fins behind the filter) become saturated with dust, pet hair, or lint. When these fins are clogged, the air cannot pass through the narrow gaps, causing the fan to spin without moving a significant volume of air, which often results in a "whirring" sound but no tangible breeze. Another common cause is "icing" or frosting of the coils. If the unit is operated in an environment below 60°F (15°C) or if the airflow is already slightly restricted, the moisture on the coils freezes into a solid block of ice. This ice physically blocks the air passages, effectively sealing the unit. You can confirm this by removing the air filter and looking directly at the metal fins; if you see a white, crystalline layer or a solid wall of ice, the unit is frozen. If the fins are gray or brown and "fuzzy," the issue is debris accumulation.

How to Fix It

To restore full suction and airflow to your Honeywell DH70W, follow these precise steps:

  1. Disconnect the power cord from the wall outlet to ensure safety and prevent the compressor from cycling during cleaning.
  2. Remove the washable air filter from the front grille. Inspect the filter for a layer of gray dust; if it is clogged, wash it with warm soapy water and let it air dry completely before reinstalling.
  3. Using a vacuum cleaner with a soft brush attachment or a narrow crevice tool, gently vacuum the evaporator coils. Move the vacuum in a vertical direction, following the orientation of the aluminum fins to avoid bending them. Do not apply heavy pressure, as these fins are thin and easily damaged.
  4. If you find ice buildup on the coils, do not attempt to scrape it off with a knife or screwdriver, as puncturing a coil will leak the refrigerant and destroy the unit. Instead, move the unit to a warmer room or use a hair dryer on a "low" or "cool" setting from 6 inches away to melt the ice.
  5. Wait 24 hours for the internal components to reach room temperature and for any hidden ice pockets inside the chassis to thaw.
  6. Wipe down the front grille slats with a damp cloth to ensure no exterior blockages are hindering the intake.
  7. Plug the unit back in and set the fan speed to "High" to test the suction strength.

If That Didn't Work

  • Check the Fan Blade Assembly: Over time, the centrifugal fan wheel can accumulate a thick layer of dust on the blades themselves, which changes the airfoil shape and reduces the amount of air it can push. Use a flashlight to look past the coils into the fan housing. If the blades are caked in dust, use a can of compressed air to blow out the fan wheel while the unit is unplugged.
  • Inspect the Capacitor: If the fan is spinning but sounds "sluggish" or slower than usual, the start/run capacitor may be failing. A weakened capacitor prevents the motor from reaching its full rated RPM, resulting in weak airflow. This requires a multimeter to test for capacitance (uF) and replacement of the capacitor if it falls below the rated value.
  • Verify the Exhaust Vent: Ensure the top exhaust vent is not blocked by curtains, furniture, or walls. If the air cannot escape the top of the DH70W, it cannot be pulled in through the front. Ensure there is at least 12-18 inches of clear space around the entire perimeter of the unit.
  • Check for Refrigerant Leaks: If the coils are not cold to the touch despite the compressor running, the unit may have a refrigerant leak. Without the cooling effect, the unit may not be pulling moisture efficiently, which can sometimes be mistaken for a fan issue. If the coils are room temperature, the sealed system has failed.

Heads Up

  • Never operate the DH70W in temperatures below 60°F unless it has a dedicated "low temperature" or "auto-defrost" mode active, as this is the primary cause of coil icing.
  • Clean the washable filter every two weeks during peak humidity months; a clogged filter is the leading cause of compressor overheating and premature motor failure.
  • Avoid using harsh chemical cleaners or bleach on the aluminum fins, as these can corrode the protective coating and lead to pinhole leaks in the refrigerant lines.
  • If the unit is used in a garage or workshop with high sawdust levels, use a secondary pre-filter (like a thin layer of cheesecloth) over the grille to prevent the internal coils from clogging.