Most likely, the electronic protection system has tripped. It shuts the tool off if the battery is overloaded or overheats.
- Remove the battery from the drill.
- Let both the drill and battery sit for 15-20 minutes to cool down.
- Reinstall the battery. Press the battery indicator button. If any LEDs light, the battery has charge.
- Pull the trigger. It should run.
IF THAT DIDN'T WORK: Try a different ONE+ 18V Lithium+ battery you know is good. If the drill works, the original battery is faulty. If it still doesn't work, the drill's internal electronics or trigger may have failed.
HEADS UP: The IntelliCell™ system protects the tool and battery from damage. If it trips repeatedly during normal use, stop. The tool or battery needs service.