All questions — page 124
Browse by Problem
-
my echo show 10 keeps saying 'sorry, something went wrong' when i try to play spotify or make a call.
This is a connectivity or account linking error. The device cannot reach the required service. Follow this checklist. Reboot your Wi-Fi router. Reboot the Echo…
-
how do i stop my echo show 10 from following me around the room, it's creepy.
The Motion feature, which uses the 13MP camera to track movement, is enabled. This is the core function of the Show 10. Disable Motion. Swipe down from the top…
-
echo show 10 screen went black but i can still hear alexa talking, is it broken?
The display has timed out or entered sleep mode, but the device itself is still powered on and functional. Wake the display. Tap the screen firmly or wave your…
-
my echo show 10 just spins in a circle constantly and won't respond to voice commands, what's wrong?
The device is stuck in its camera tracking or 'Motion' mode. The microphones are likely muted, indicated by the red light ring. First, check the microphone sta…
-
fan runs but compressor keeps clicking on and off every few minutes, not dehumidifying right
That rapid cycling is usually the unit hitting its internal high-pressure limit and shutting the compressor down as a safety measure. The most common cause is …
-
display says 'cl' and it won't run, i just cleaned the filter yesterday
'CL' is the Clean Filter indicator. It's not based on time since you cleaned it; it's based on total runtime hours. The unit has an internal timer that trigger…
-
the continuous drain hose setup is leaking where it connects to the back of the unit
Leaks at the hose port are almost always because the standard garden hose adapter isn't seated correctly or the rubber gasket inside is missing/misaligned. The…
-
how do you clean the filter on this thing? i can't find a latch or anything to get it out.
The filter access isn't super obvious. The washable filter is behind the front grille, which is a single piece that snaps off, but it feels stuck if you don't …
-
it's running but not collecting any water, bucket stays empty and humidity isn't dropping
If it's blowing air but not condensing water, the refrigerant system isn't working. The most common culprits are either a frozen evaporator coil (because it's …
-
unit won't turn on at all, no lights, nothing. checked the outlet and it's fine.
Total silence usually points to an internal safety fuse on the main control board. These have a small fuse that can blow from a power surge or a compressor sta…
-
tosot 50 pint pump model is making a loud grinding noise when the pump kicks on, sounds awful
That grinding or rattling is almost always air in the pump line or a dry pump. The internal condensate pump isn't designed to run dry, and if the water path fr…
-
my tosot dehumidifier just keeps beeping e2 and won't start pulling water, what is that?
Yeah, this one's common. The E2 error code on these units specifically means the water bucket is full, or the sensor thinks it's full. It's the unit's way of t…
-
the control panel buttons are beeping but not responding when i press them.
The control board is receiving power (hence the beep) but is locked up, usually from a brief voltage spike or a child lock feature being activated. Perform a h…
-
it's blowing out air that doesn't feel warm at all, i thought dehumidifiers made warm air?
Your observation is correct for many dehumidifiers, but this model uses a slightly different cycle. The exhaust air temperature is much closer to room temp, wh…
-
i'm trying to use the continuous drain hose but water is still filling the bucket.
The drain hose isn't seated correctly or has an air lock. The unit's internal pump (if equipped) or gravity drain needs a clear, downward-sloping path. First, …
-
the fan keeps running after i turn the unit off or unplug it, is it haunted?
Not haunted. This is the 'dry fan' feature. It runs for 2-3 minutes after the compressor stops to dry out the internal coils and prevent mold/mildew. It's auto…
-
my dehumidifier is making a loud gurgling or bubbling noise, is that normal?
Yes, this is normal during the defrost cycle. The unit temporarily reverses to melt ice off the coils, and you're hearing refrigerant moving through the system…
-
how do i clean the actual inside of my vremi 4500? the manual is vague and i'm scared to break it.
Mineral scale and dust build up on the evaporator and condenser coils inside, drastically reducing efficiency and causing ice-up. For a basic clean, power off …
-
vremi dehumidifier is running but not collecting any water, what gives?
The compressor is running but the coils aren't getting cold enough to condense moisture. This is usually an environmental issue, not a machine failure. Check t…
-
my vremi dehumidifier just shows a continuous red light and won't run, what's that mean?
The continuous red light is the 'tank full' indicator. The unit has a safety float that stops operation when it thinks the internal bucket is full, even if you…
-
the display is showing 'CH' or 'dH' and beeping, and it won't run. what does that mean?
That's a continuous humidity sensor error. The unit's internal sensor that reads room humidity is either faulty, disconnected, or giving a nonsensical reading.…
-
my dehumidifier suddenly turned off and now it won't turn back on at all, no lights, nothing.
Complete power loss usually points to a tripped internal thermal fuse, a problem with the outlet, or a failed control board. First, eliminate the easy stuff. 1…
-
how do you clean this thing? the manual is confusing about the actual coils and stuff inside.
Regular cleaning is crucial for performance, and the main targets are the air filter, the evaporator coils you can see behind it, and the bucket. 1. Unplug it.…
-
the fan on my lg 50-pint is running but no water is collecting in the bucket, it's been days.
The compressor isn't kicking on to cool the coils and condense moisture. This could be a few things, but start with the simplest: the room might not be humid e…
-
trying to connect my puricare dehumidifier to the lg app but it won't find the device during setup.
The Wi-Fi setup process is finicky and often fails if you don't follow the exact sequence or if your phone's settings aren't right. 1. On the dehumidifier, pre…
-
my ud501k says 'full' on the display and shuts off but the bucket is only half full, what's going on?
The internal float switch, which tells the unit the bucket is full, is being triggered early. This is almost always because the bucket isn't seated perfectly o…
-
got an LG 50-pint and it's making a loud gurgling or water-sloshing noise, like there's a bucket inside it. is that normal?
That's usually the sound of refrigerant moving through the coils, which is normal during startup and operation, but if it's constant and loud, the unit might b…
-
my lg dehumidifier just flashes the red filter light even though i cleaned the filter, how do i make it stop?
The machine thinks the filter hasn't been reset after cleaning. There's a separate reset step you have to do. First, make sure the filter is completely dry and…
-
how do i really clean this thing? the manual is vague. i know mold can grow inside.
Moisture and dust inside the cabinet lead to mold on the evaporator coil and in the water reservoir areas. This causes musty smells and reduces efficiency. Unp…
-
the fan on my unit runs but the compressor never turns on. no cold air from the grille. just acts like a fan.
The compressor is not receiving the signal to start. This is usually due to the humidistat setting, a failed start capacitor, or a locked compressor. Set the h…
-
my honeywell dehumidifier turns on for a minute then shuts off. the fan stops. it does this over and over.
This is a frost sensor trip. The evaporator coil is getting too cold, likely because the room temperature is low or the air filter is blocked. First, check and…
-
i'm trying to use the continuous drain hose but water is still filling up the bucket instead of going out the hose.
The internal drain pump is not activating. On the TP70WKN, the pump only runs when the bucket is removed and a hose is attached to the port. The pump has a sep…
-
there's a loud rattling or buzzing noise coming from the back of my dehumidifier, mostly when the compressor kicks on.
The noise is from loose components vibrating against the cabinet. The most common source is the rear access panel or the copper refrigerant tubing lines. Unplu…
-
the wifi on my tp70wkn just stopped connecting. it was working before. app says offline. i already tried resetting my router.
The dehumidifier's WiFi module has likely lost its connection profile or entered a low-power state. A power cycle at the unit is required. Unplug the dehumidif…
-
just got this 70-pint honeywell, followed the setup, but it's not pulling any water out of the air after hours. fan runs fine.
This is almost always a refrigerant issue from improper transport. If the unit was laid on its side, compressor oil can migrate into the refrigeration lines, b…
-
my honeywell tp70wkn dehumidifier just shows a constant 'cL' on the display and won't run, what is that?
The 'cL' error code means the internal bucket is full or the full-bucket float switch is stuck in the up position. The machine shuts off to prevent overflow. F…
-
i just got it and the wifi/app setup won't work, it never finds the device during pairing
The most common cause is an incompatible 5GHz Wi-Fi network. The Midea Air app and device require a 2.4GHz network for setup. Ensure your smartphone is connect…
-
it shuts off after only a few minutes of running, not because the bucket is full, what's wrong?
This is typically a defrost cycle or an over-temperature condition triggering the auto-shutoff. Verify the room temperature. If the room is below 65°F (18°C), …
-
the bucket is full light comes on even when it's completely empty, unit shuts off and won't run
The float switch in the bucket reservoir is stuck in the "up" position or is misaligned. Remove the bucket. Inspect the small white float at the back of the bu…
-
how do i clean the filter on this thing? i can't find where it's at on my midea
The washable air filter is located behind the front grille. It must be cleaned every 2-3 weeks for proper airflow and efficiency. Power off and unplug the unit…